Back to Overview

Functional principle of NDH15K Arc resistance tester

Feb 26,2025

Functional principle of NDH15K Arc resistance tester

Insulation materials have the ability to resist deterioration caused by high voltage arc action , usually a standard arc flame is used to induce carbonization on the surface of the material until the surface  is  conductive.The  time  required  for  the  arc  to  disappear  is  expressed  in  second.  Add two tungsten electrodes separated by a certain distance on the plate sample, at first the arc is intermittent, then gradually shortened,and finally continuous arc with gradually increasing current,the material is subjected  to  increasingly  severe  arc  conditions  and  eventually  fails.Arc  resistance  is  important  for insulating materials used  in high-voltage  switches  or  low-voltage  high-current  switches,because  the switch is often affected by arc when it is opened and closed, only materials with good arc resistance can be selected.

Insulating material used in the interior of electrical and electronic equipment, when exposed to a

high-voltage, low-current arc discharge, is tested the differences in surface damage close to the arc.The arc discharge causes local thermal and chemical decomposition and corrosion and eventually forms a    conductive channel on the insulating material ,When a conductive channel is formed in the tested

material, the material can be determined to have failed.

Arc resistance tester is GB1411, IEC61621, ASTMC495, UL746A and other standards of the simulation safety test project necessary special instrument.

The arc resistance tester is composed of electrical schematics and electrodes according to the following standard requirements
 