GZRM-XII series Xenon arc lamp artificial climate aging test chamber
+
  • GZRM-XII series Xenon arc lamp artificial climate aging test chamber

Model GZRM-XI45

Economical and simple design Xenon lamp aging instrument, With all the advantages of XⅡ series products. Equipped with 4500W water-cooled xenon lamp, the exposure test area is 2188cm2.

Model GZRM-XII 65

Medium-sized accelerated aging tester that complies with international testing standards, equipped with a 6500W water-cooled xenon lamp, the exposure test area is 6500cm² .

Model GZRM-X II75

Medium-sized accelerated aging tester that complies with international testing standards,equipped with

7500W water-cooled xenon lamp, exposure test area of 7500cm². It can do more than 180W@300-400mm irradiance test.

Model GZRM-XII1200

The most advanced accelerated aging tester with the largest sample capacity ,equipped with 12000W water-cooled xenon lamp, exposure test area of 11000cm² .

 

GZRM-XIIseries Xenon arc lamp artificial climate aging test chamber 

Technical features and indicators:

1 、Rotary drum test stand ,Fully and evenly expose to each sample.

2、Optional narrow wavelength 340nm, 420nm or wide wavelength 300~400nm.Light irradiance automatic control system,and real-time monitoring and display function.Meet all test requirements worldwide.

3 、High irradiance control:The control light irradiance can reach 2 solar or higher levels.

4 、The light irradiance is adjustable, controllable and stable.

5 、Sample holder temperature:Blackboard temperature 、The black standard temperature is monitored and controlled in real-time.Good stability and repeatability during the test.

6 、Automatically control the sample environment temperature and sample surface temperature at the same time.(Blackboard temperature, black standard temperature)

7 、Relative humidity control.Can meet global, rigorous test methods.

8、More accurate control of temperature and humidity through the damper actuator.Avoid affecting accuracy and repeatability due to changes in relative humidity and laboratory environment.

9 、Simulate different outdoor test conditions through internal and external filters.

10 、With water quality monitoring, alarm function. It’s a test chamber that meets the global xenon lamp aging test standards:

GZRM-X45, using 4500W water-cooled xenon lamp ,the exposure area is 2188cm²

GZRM-X65, using 6500Wwater-cooled xenon lamp ,the exposure area is 6500cm²

GZRM-X75, using 7500Wwater-cooled xenon lamp ,the exposure area is7200cm²

GZRM-X1200, using12000Wwater-cooled xenon lamp ,the exposure area is11000cm²

GZRM-XII series xenon lamp aging test chamber applicable standard:

Standard

Number

AATCC

TM16

TM169

 

 

ASTM

G151

G155

D6695

 

Ford

DVM0067MA

 

 

 

GME

60292

 

 

 

GMW

3414

 

 

 

ISO

105-B02

105-B04

105-B06

 

 

11341

3917

48922

12040

JASO

M346

 

 

 

MIL STD

810F

 

 

 

SAE

JI885

J1960

 

 

VDA

621-429

621-430

75202

 

VW

PV121

PV1303

PV3929

PV3930

 

GZRM series xenon lamp technical features:

Technical indicator

GZRM-XII1200

GZRM-XII75

GZRM-X1165

GZRW-X1145

Water-cooled xenon lamp with long life and quick installation

 

12000M

 

7500W

 

6500W

 

4500W

Stainless steel drum test rack, exposure area

 

11000cm²

 

7200cm²

 

6500cm²

 

2188 cm²

Light irradiance automatic

control@340nm;@420nm;@300- 400nm

Multi-language touch screen

Test parameter setting and display

Automatic blackboard

temperature control system on the holder

Test chamber automatic

temperature control system

Blower speed automatic control

Control the end time by radiation amount(KJ/M²)

Lamp cooling resistivity tester

Smart DamPerTm

Calibration reference xenon lamp

VibraSonicTm Humidification system

Automatic humidity control system

Direct relative humidity reading(%RH)

The touch screen displays diagnostic information

Main power off switch

Signal transmitter

Instrument base size (Including access area,cm)

124×145

110×130

110×130

82×94

Cooling accessories in test box

(Low temperature test requirements)

Lamp cooling water cooling device

LiquiAIRTm Xenon lamp cooling system

Data logger

Data acquisition system (Multiple

aging test chambers are  controlled by computer)

Blackboard/Black standard dual channel control and monitoring

Multiple temperature sensors on sample holder

Second wavelength monitoring

Annotation:●Standard configuration        ■Optional configuration

 

Xenon lamp and metal halogen simulate different conditions

 

Composition of filter

Test condition

 

Irradiation intensity at different wavelength W/m²

 

Inner

Outer

Xenon lamp simulation conditions

 

300-400

nm

300-800

nm

300-3000

nm

340

nm

420

nm

GZRM series

Borosilicate

Borosilicate

Simulate outdoor   climate conditions

Min

 

Max

29

 

151

 

 

4.3

 

1.6

0.6

 

3.0

Borosilicate

Soda glass

Through glass (indoor) test

Min

 

Max

28

 

136

 

 

0.3

 

1. 1

0.6

 

3.0

Quartz

Borosilicate

Simulate UV, stronger than sunlight

Min

 

Max

33

 

171

 

 

0.3

 

1.6

0.6

 

3.2

Soda lime

Borosilicate

Simulates daylight but at a lower temperature

Min

 

Max

34

 

181

 

 

0.3

 

1.7

0.6

 

3.2

GRRM- AIR

series

Window glass

Spraying quartz

Simulates sunlight under window glass

Min

 

Max

 

251

 

764

 

 

 

 

Special UV glass

Spraying quartz

Simulate outdoor sunlight

Min

 

Max

 

251

 

767

 

 

 

 

Solar

standard

Spraying quartz

UV that simulates the intensity of outdoor    sunlight

Min

 

Max

 

251

 

165

 

 

 

 

ID 65+  window glass

Spraying quartz

Simulate sunlight under a 6MM thick window

glass

Min

 

Max

 

252

 

766

 

 

 

GRRH- SC

series

Wide

outdoor

conditions

 

 

Simulates sunlight under window glass

Min

 

Max

 

 

750

 

1250/100 0

 

 

 

Wide

outdoor

conditions

 

 

Simulate outdoor

sunlight conditions

Min

 

Max

 

 

900

 

1500/120 0

 

 

 

Comparison between solar spectrum and lab light source spectrum

 

 

The test chamber is made of high quality stainless steel,Resistant to acid, alkali and high intensity light radiation

Sample holder type:AH-type ,Three layer structure exposure area:

GZRM-X45 series:2188cm², 22 standard sample plate(145mm×70mm)

GZRM-X65series:6500cm², 65 standard sample plate(145mmX70mm)

GZRM-X75 series:7200cm², 72 standard sample plate(145mmX70mm)

GZRM-X1200 series:11000cm², 111 standard sample plate(145mmX70mm)

Test chamber internal test holder

Keywords

GZRM-XII series Xenon arc lamp artificial climate aging test chamber
+
  • GZRM-XII series Xenon arc lamp artificial climate aging test chamber

GZRM-XII series Xenon arc lamp artificial climate aging test chamber

Plastic materials are characterized by thermal properties, resistance to stretching, bending, weathering, and electrical insulation.

Classification


Get A Quote

Note: Please leave your contact information and our professionals will contact you as soon as possible!

Submit