KXRW-300CL-3 Heat Distortion and Vicat Softening Point Temperature Tester

Overview
It is mainly used for determining the heat distortion temperature and Vicat softening point temperature of non-metallic materials such as plastics, hard rubber, nylon, electrical insulating materials, long-fiber reinforced composite materials, and high-strength thermosetting laminated materials. It is easy to operate and precise in control, making it a highly intelligent testing instrument. It is widely used in colleges and universities, scientific research institutions, and product quality supervision and inspection units.
Compliance with Standards
It meets the requirements of standards including GB/T 1633, GB/T 8802, GB/T 1634, ISO 2507, ISO 75, ISO 306, ASTM D 1525, and ASTM D 648.
Instrument Features
- Test Stand Lifting System
The automatic lifting function of the test stand greatly facilitates test operation, improves test efficiency, and avoids personal injury.
- Advanced Control System
It features ultra-high stability and is easier to install, operate for testing, and conduct analysis.
- User-Friendly Software Control System
It simulates nixie tube display for temperature and displacement, draws test curves, provides multiple coordinate curves, conducts centralized data management, and enables analysis of test data, as well as printing of test curves, test data, and test reports.
- Four-Fold Safety Protection
Multiple software and hardware safety designs, such as mechanical upper temperature limit protection switch, software upper temperature limit protection, automatic stop after test completion, and administrator operation key, ensure the safe and stable operation of the test.
- High-Precision Measurement and Control System
It adopts a high-performance temperature sensor and an advanced capacitive grid digital micrometer to accurately measure the micro-deformation of samples. An advanced PID algorithm and a fully photoelectrically isolated phase-shifting module are used for temperature rise control, ensuring that the temperature rise rate error is within 0.5℃.
Technical Parameters
- Temperature rise rate: 50±5℃/h ~ 120±10℃/h, adjustable arbitrarily
- Number of test pieces: Can test three groups of components simultaneously
- Deformation measurement device: Micrometer with 0.001mm resolution and 0.001mm accuracy
- Overall dimensions (length × width × height, mm): Approximately 770×350×630
- Power supply: AC 380V, 1.5kW
- Weight: Approximately 80kg
- Temperature accuracy: Class 0.2
- Temperature control range: Room temperature ~ 300℃
- Temperature measurement points: 1
- Deformation measurement range: -0.1 ~ 10mm
- Maximum deformation error: ±0.005mm
- Deformation resolution: 0.001mm
- Sample support span: 64mm, 100mm
- Equipped with software upper temperature limit protection function and hardware upper temperature limit protection function (the temperature switch is imported from South Korea, with a current of 30A, which is not false protection; the heating power is 4000W, ensuring that the temperature can be raised to 300℃ at a rate of 120℃/h)
- Automatic lifting of the sample stand; the thermal expansion coefficient of the sample stand itself is < 0.005/100℃ (key point, directly affecting the test results)
- Control method: Adopting a distributed control system with a single-chip microcomputer and a PC
- Equipped with an automatic lifting system for the sample stand
- Working medium: Methyl silicone oil or transformer oil
- Cooling method: Natural cooling above 150℃; water cooling or natural cooling below 150℃
Configuration
| Name | Origin and Purpose | Quantity |
| Main unit | ZNYQ | 1pc |
| Sample stand | ZNYQ | 3pcs |
| Heat distortion indenter | ZNYQ | 3pcs |
| Vicat indentor | ZNYQ | 3pcs |
| Brand desktop computer | Lenovo | 1pc |
| Printer | HP | 1pc |
| Test software | ZNYQ | 1pc |
| Power cord | ZNYQ | 1pc |
| Signal communication cable | ZNYQ | 1pc |
| Weight | ZNYQ | 1set |
| Digital remote-transmission micrometer (range: -0.1 ~ 10mm) | ZNYQ | 3pcs |
Test Software: