Technical Parameters of the Test Chamber
| Total Exposure Area | 2200cm2 | |
| Working Chamber Dimensions | 580×690×580 (W×H×D in mm) | |
| Temperature Range | Working Chamber Temperature | 35℃~90℃ |
| Black Panel Temperature | 40℃~110℃ | |
| Black Standard Temperature | 40℃~120℃ | |
| Relative Humidity Range | Light Exposure | 10~75% |
| Dark Period | 10~95% | |
| Light Irradiance | Optional automatic control for wavelengths of 340nm, 420nm, or 300~400nm | |
| Sample Rack Type | Single-layer structure | |
| Test Sample Holder | 22 standard holders (150×70mm) or customized according to user requirements | |
Main Advantages
|
|
|
|
|
|
|
|
|
|
|
Operating Environment Conditions
| Ambient Temperature | Room temperature not exceeding 30℃ |
| Ambient Relative Humidity | <80% |
Temperature
| Temperature Range | Working Chamber Temperature | 35℃~85℃ |
| Black Panel Temperature | 40℃~110℃ | |
| Black Standard Temperature | 40℃~120℃ | |
| Temperature Fluctuation | ±2℃ | |
Humidity
| Relative Humidity Range | Light Exposure | 10~75% |
| Dark Period | 10~95% | |
| Relative Humidity Fluctuation | ±4% | |
Light Irradiance
| Light Irradiance | Optional wavelengths of 340nm, 420nm, or 300~400nm, automatic control (0.30-1.60) W/㎡@340nm; (0.60-3.00) W/㎡@420nm; (30-180) W/㎡@300-400nm; W/㎡@340nm · |
| Light Irradiance Deviation | ±0.02W/m2@340nm\@420nm; ±2W/m2@300-400nm; |
| High Irradiance Intensity Control | Can reach 2 suns or higher levels |
| Total Exposure Area | 2200cm2 |
| Standard Test Sample Holder | 22 holders (150mm×70mm) or customized according to user requirements |
| Light Irradiance Calibration Function | Calibrated with calibration xenon lamp or irradiance calibration meter, verified by national metrology authorities |

Spectral Comparison Between the Light Source of GZRM-X Series Xenon Arc Lamp Artificial Climate Test Chamber and Sunlight
Test Methods and Procedures
| Test Methods and Program Capacity | Fixed: 12 international and national xenon lamp aging test standards |
| Editable: 4 programs, maximum 150 program segments can be set | |
| Simulation of Different Test Conditions | Using different internal and external filters: Boro/Boro, Quartz/Boro, Quartz/Quartz, Boro/Sodalime, etc. |
| Light/Dark Cycle | Automatically controlled, real-time monitored and displayed |
| Satisfied Test Standards | GB/T1865-2009 GB/T16422.2-2014 GB/T1189-1991 GB/T12527-2008 GB/T18244-2000 GB/T14049-2008 GB/T8430-1998 GB/T2423.24-2013 SAE_J_2412_2004-旧1885 ;SAE J2527-旧1960 ISO 105B-06 ;ISO 105B-02 ;ISO 105B-04 ISO4892-2 ;ISO11341 AATCC16E ;AATCC169(1) JASOM346-93 IEC 68-2-18 MS 200-42-2009 E_M0135_2001-N GMW3414TM Ford Interior ASTM G155-1 ASTM G155-4 ASTM G155-5 ASTM G154 ASTM G151 ASTM D5423 ASTM D4459 |

Simulation of Different Test Conditions by Different Filters
Main Control Systems
Xenon Lamp Automatic Control System
| Control Method | Automatic control to ensure that xenon lamp irradiance does not attenuate with xenon lamp aging |
| Calibration | Using calibration xenon lamp or irradiance calibrator System comes with built-in calibration program |
| System comes with built-in calibration program | |
| Water Cooling Method for Water-Cooled Xenon Lamp | Automatic control of cooling water temperature |
| Imported high-quality water pump | |
| Environmentally friendly water-saving design | |
| Water shortage protection function with flow switch | |
| Water-Cooled Xenon Lamp (American ATLAS) | 4.5KW, service life exceeding 2000 hours, easy to disassemble |
Light Irradiance Calibration Function
This product adopts the automatic calibration function of standard xenon lamp. Every 400 hours, an alarm message will remind the user. It ensures the accuracy of light irradiance, a key indicator during the xenon lamp aging test, and the standard xenon lamp has been tested by the National Institute of Metrology, China, an authoritative national institution.

Touchscreen

Instrument Acceptance and Metrological Traceability
Acceptance Outline:
Xenon lamp aging test chamber
Chamber Temperature
Black Panel/Black Standard Temperature
Relative Humidity
Light Irradiance
Appearance and Accessories
Local Metrology Institute
Local Metrology Institute
National Institute of Metrology, China
Local Metrology Institute
Light Irradiance Calibration Standard:

Parameter Traceability
Traceability: Measurement results can be traced to international or national standards.
Traceability Diagram
International Bureau of Weights and Measures (BIPM)/Reference Materials
National Bureau of Metrology/Reference Materials
Temperature (Sample Rack Temperature/Working Chamber Temperature)
Relative Humidity
Light Irradiance (@340nm;@420nm,300-400nm)
Calibration Xenon Lamp
Irradiance Calibration Meter


Keywords
Xenon Arc Lamp Artificial Climate Aging Test Chamber