Test chamber profile:

Fluorescent ultraviolet aging test chamber, mainly using fluorescent ultraviolet UVA, UVB, UVC as the light source, by changing the temperature (sample shelf temperature), relative humidity, rainfall mode, etc., to simulate the outdoor climate test conditions of UV light, heat and water comprehensive combination, the test material photochemical energy and mechanical properties of artificial aging test. The main control parameters are automatic control of light irradiance, sample shelf temperature (blackboard temperature), etc. The instrument adopts advanced controller PLC, advanced and stable control; There are various alarm information in the control process, and the maintenance is good. The device conforms to domestic xenon lamp aging test standards and international standards ATTCC, ISO, DIN, ASTM, etc. Suitable for a wide range of plastics, coatings, rubber, textiles, automobiles, building materials and so on. The instrument control system includes: irradiance automatic control system; Temperature control system; Condensation control system; Guarantee alarm system composition.

Technical specifications:

Product nameFluorescent aging test chamber        
Product modelUV-40-8II           
Sample requirementsThis test equipment is prohibited : Testing or storage of samples of flammable, 
  explosive and volatile substances, testing or storage of samples of corrosive 
  substances, testing or storage of biological samples, testing or storage of samples of 
  strong electromagnetic emission sources       
Temperature rangeBlack panel temperature(BPT):40~90℃       
  Temperature control range of light cycle: 40~80℃     
  Temperature control range of condensation cycle: 40~60℃    
Temperature fluctuation±1℃           
Relative humidityDuring condensation≥95%        
Irradiance control modeAutomatic control of light irradiance       
Condensation methodNickel chromium alloy electric water heating condensation system   
Whole machine power2KW           
 Type of light sourceUVA or UVB Fluorescent ultraviolet tube(The normal service life is mo 
 than 4,000 hours)          
Light           
PowerOne 40W           
            
sourceWavelength rangeUVA:340nm、UVB:313nm; UVC modulator tube     
Control rangeUVA:0.25~1.55 W/m2 UVB:0.28~1.25W/m2UVC:0.25~1.35 
  W/m2           
 IrradianceAutomatic control of light irradiance       
 Inner shell materialStainless steel plate SUS304#        
 Housing materialHigh quality coated steel plate (off-white)       
 Insulation layerRigid foam           
 Air heatingNickel-chromiumalloyheating,heatingcontrol: nocontactSSR(solidstate 
 relay)           
             
iConstWater heatingNickel-chromiumalloyheating,heatingcontrol: nocontactSSR(solidstate 
relay           
            
Number of light tubes8pieces , UVA or UVB UVC fluorescent UV tubes     
tetu             
Man-machine touchSiemens products, LCD display, easy to operate      
 screen      
 Control systemUsing Siemens PLC         
 Sample holderUsing pure aluminum metal, the distance from the sample surface to the center 
 of the light tube is 50±3mm        
          
 Standard template24 standard sample racks (75×300mm, i.e. two 75×150mm standard samples) 
 Irradiance calibratorIrradiance meter RM-10(National metrological verification)    
ctChara SAEJ2020,PREN1062-4,ISO4892-3,ASTM G53,ASTM 
StandardsG154,EN534,DIN74324.1-1996,Q/YQ 2155- 2010,Q/YQ2164-2012 
tirise GB16897-2010,GB/T16422.3,ISO11507 etc. or set it yourself    
 Different test methodsAutomatic control, real-time monitoring and display 
 and procedures    
 SamplerackSample shelf temperature BPT direct display and automatic control 
 temperature    
 Condensation controlDirect condensation display and automatic control 
 Circulation modeDirect display and automatic control of light, condensation, spray, light + spray 
 Light irradiance Light irradiance and time can be set during the test 
 Spray water Adjustable and display, automatic control, the test process can be set spray time 
 Calibration functionAutomatic temperature calibration, convenient and fast 
      
 Alarm Automatic alarm function  
 Water supply methodAutomatic water supply  
Protector Leakage protection, watershortage protection, heating overload protection,do 
 safety protection, over-temperature protection, irradiance abnormal alarm 
    
External dimensions 1200×1500×450mm(W×H×D) 
Power supply Single phase; 50/60Hz;15A 

Our advantages:

  • Manual interface touch screen, easy to operate

Light irradiance is adjustable and controllable, with high irradiation intensity control function Perfect sample temperature control system, with overtemperature protection function

  • Professional and reasonable studio design and air circulation system ensure the uniformity and accuracy of sample test
  • Automatic control of illumination and condensation, which can meet the strict test methods
  • Environmentally friendly fluorescent UV cooling system

Has the dual functions of low water level alarm and automatic water refill The machine is made of high quality spray material, durable and beautiful The machine is made of high quality stainless steel, durable and beautiful

Control System---Fluorescent purple automatic control system

Control modeAutomatic control to ensure that irradiance does not 
decay with xenon lamp aging 
  
CalibrationA calibrated irradiance meter is used 
  
The system comes with calibration procedures 
  
   
Cooling methodAutomatic controlled cooling 
  
   

Control system of temperature and humidity

Protection system

Main power supply, branch powerSiemens switch 
switch 
  
   
 Water shortage protection 
   
 Over temperature protection 
   
Heating systemLow (high) irradiance value alarms 
 Low cooling water level protection 
   
 Door safety protection 
   
Temperature controllerSample rack temperature over-temperature protection 
  
Sample shelf temperature low alarm 
  
   
OtherLeakage, over-current overload protection 
   
Lightning protection performanceThe lightning induced voltage is less than 5KV, the 
lightning induced current is less than 1700A, and the 
  
 response time is less than 10-12 seconds 
   
Human machine interface touch screenSiemens touch screen 
   

Touch screen:

Radiation calibrator:

Water purifier:

Pure water machine device

Place standard template

Place the rubber seal properly Install sample rack

Ⅱ、Power supply

1、Single phase,AC220V,50Hz,with good grounding.

2、maximum current 12A,It is recommended to choose a high quality overcurrent and leakage protection of the main switch, the use of more than 2.5 square power bus.

3、The main power interface of the test chamber is located at the bottom right front of the chamber。Ⅲ、source of water

1、Hydraulic pressure: 138~344Kpa(20~50psi) ;Rate of flow:min 5L/min。

2、Spraying and humidifying water: It is required to reach the national analysis laboratory level II water quality, and the solid impurity content of water is less than 1mg/L。

Matters need attention:

  1. The temperature and humidity accuracy test mentioned in the standard is measured in the studio without test items, the test environment is stable, and there is no heating load.

2, the change of temperature and humidity is affected by the size, amount and heat dissipation of the sample to be measured.

3, in order to continuously improve our products, we reserve the right to explain the product structure design. Other technical designs can be explained separately if requested.

 

Keywords

Fluorescent UV Aging Test Chamber UV-40-8II
Fluorescent UV Aging Test Chamber UV-40-8II
Fluorescent UV Aging Test Chamber UV-40-8II
Fluorescent UV Aging Test Chamber UV-40-8II
Fluorescent UV Aging Test Chamber UV-40-8II
+
  • Fluorescent UV Aging Test Chamber UV-40-8II
  • Fluorescent UV Aging Test Chamber UV-40-8II
  • Fluorescent UV Aging Test Chamber UV-40-8II
  • Fluorescent UV Aging Test Chamber UV-40-8II
  • Fluorescent UV Aging Test Chamber UV-40-8II

Fluorescent UV Aging Test Chamber UV-40-8II

Fluorescent UV Aging Test Chamber UV-40-8II

Classification


Get A Quote

Note: Please leave your contact information and our professionals will contact you as soon as possible!

Submit