DSC-500A Touch Screen Differential Scanning Calorimeter
DSC-500A Touch Screen Differential Scanning Calorimeter
DSC-500A Touch Screen Differential Scanning Calorimeter
DSC-500A Touch Screen Differential Scanning Calorimeter
DSC-500A Touch Screen Differential Scanning Calorimeter
DSC-500A Touch Screen Differential Scanning Calorimeter
DSC-500A Touch Screen Differential Scanning Calorimeter
+
  • DSC-500A Touch Screen Differential Scanning Calorimeter
  • DSC-500A Touch Screen Differential Scanning Calorimeter
  • DSC-500A Touch Screen Differential Scanning Calorimeter
  • DSC-500A Touch Screen Differential Scanning Calorimeter
  • DSC-500A Touch Screen Differential Scanning Calorimeter
  • DSC-500A Touch Screen Differential Scanning Calorimeter
  • DSC-500A Touch Screen Differential Scanning Calorimeter

KDSC-500A  Differential Scanning Calorimeter

 

1. Functions

KDSC-500A can be employed for the characterization of a great variety of materials. It is used in polymers; and here not only in plastics and rubber processing, but also in the pharmaceutical and, food packaging and technical textiles.

Differential scanning calorimeter (DSC) as a programmable temperature of the heating effect of the classical thermal analysis method, in today's all kinds of material and in the field of chemical industry research and development, process optimization, and quality control, quality control and failure analysis, etc. Various kinds of occasions have been widely applied. Using DSC method, we can accurately test the oxidation induction time of materials. Widely used in plastic, rubber, paint, food, medicine, biological organisms, inorganic materials, metal materials and composite materials

 

standards-compliant

       GB17391-1998, ISO/CD11357/6

Characteristics

Touch screen display, display information is very more, including setting temperature, sample temperature, oxygen flow, nitrogen flow, differential thermal signal, all kinds of switch state

USB communication interface, generality is strong, reliable communication don't interrupt, support the restore connection function.

Furnace structure is compact, arbitrary adjustable cooling rate.

Improved installation process, all adopt the machinery fixed way, completely to avoid contamination of furnace inside colloid to differential thermal signal.

Double temperature probe, make sure the height of the sample temperature measurement repeatability. Temperature sensor is installed on furnace walls all the way, used for PID control of the furnace body temperature, but due to the temperature of thermal inertia, conduction to the temperature on the sample have some deviation, and deviation degree of four seasons is different, therefore, with one temperature probe temperature control and temperature measurement, differential thermal signals and temperature signals, the error is larger; The instrument in the bottom of the sample how to install a temperature probe, used to measure the real temperature of the sample, and used our special temperature control technology, control the temperature of furnace wall temperature to reach the set temperature.

Digital gas mass flow meter atmosphere automatic switching two way traffic, fast switching and stable time is short.

Standard samples, convenient customer constant temperature correction coefficient.

Software adaptive resolution of computer screens, each software automatically according to the computer screen size to adjust the curve display mode. Support for notebook, desktop; Support the Win2000, XP, VISTA, Windows 7 operating system, etc

Support user programming procedures, to achieve fully automated measuring step. Software provides dozens of commands, users can according to your own measurement steps, and combined the orders, and save. Complex operation is simplified into a key operation.

Parameters:

  1. Temperature range: RT-500℃
  2. Temperature resolution:0.01℃
  3. Heating rate: 180℃/min  
  4. Cooling rate:130℃/min  
  5. DSC range: 0±500mW
  6. DSC resolution: 0.02mW
  7. Working power: AC 220V 50Hz 300W or other
  8. Gas pressure:0.2MPa
  9. Gas flow accuracy: 0.2mL/min

Configuration list:

  1. A DSC machine
  2. 300 Aluminium crucibles
  3. A power cords and a USB cable
  4. A CD (contains software and operations video)
  5. Oxygen airway and nitrogen airway, each 5m
  6. A operation manual

 

Keywords

DSC-500A Touch Screen Differential Scanning Calorimeter
DSC-500A Touch Screen Differential Scanning Calorimeter
DSC-500A Touch Screen Differential Scanning Calorimeter
DSC-500A Touch Screen Differential Scanning Calorimeter
DSC-500A Touch Screen Differential Scanning Calorimeter
DSC-500A Touch Screen Differential Scanning Calorimeter
DSC-500A Touch Screen Differential Scanning Calorimeter
+
  • DSC-500A Touch Screen Differential Scanning Calorimeter
  • DSC-500A Touch Screen Differential Scanning Calorimeter
  • DSC-500A Touch Screen Differential Scanning Calorimeter
  • DSC-500A Touch Screen Differential Scanning Calorimeter
  • DSC-500A Touch Screen Differential Scanning Calorimeter
  • DSC-500A Touch Screen Differential Scanning Calorimeter
  • DSC-500A Touch Screen Differential Scanning Calorimeter

DSC-500A Touch Screen Differential Scanning Calorimeter

KDSC-500A  Differential Scanning Calorimeter 1. Functions:KDSC-500A can be employed for the characterization of a great variety of materials. It is used in polymers; and here not only in plastics and rubber processing, but also in the pharmaceutical and, food packaging and technical textiles.Differential scanning calorimeter (DSC) as a programmable temperature of the heating effect of the classical thermal analysis method, in today's all kinds of material and in the field of chemical industry research and development, process optimization, and quality control, quality control and failure analysis, etc. Various kinds of occasions have been widely applied. Using DSC method, we can accurately test the oxidation induction time of materials. Widely used in plastic, rubber, paint, food, medicine, biological organisms, inorganic materials, metal materials and composite materials standards-compliant:       GB17391-1998, ISO/CD11357/6CharacteristicsTouch screen display, display information is very more, including setting temperature, sample temperature, oxygen flow, nitrogen flow, differential thermal signal, all kinds of switch stateUSB communication interface, generality is strong, reliable communication don't interrupt, support the restore connection function.Furnace structure is compact, arbitrary adjustable cooling rate.Improved installation process, all adopt the machinery fixed way, completely to avoid contamination of furnace inside colloid to differential thermal signal.Double temperature probe, make sure the height of the sample temperature measurement repeatability. Temperature sensor is installed on furnace walls all the way, used for PID control of the furnace body temperature, but due to the temperature of thermal inertia, conduction to the temperature on the sample have some deviation, and deviation degree of four seasons is different, therefore, with one temperature probe temperature control and temperature measurement, differential thermal signals and temperature signals, the error is larger; The instrument in the bottom of the sample how to install a temperature probe, used to measure the real temperature of the sample, and used our special temperature control technology, control the temperature of furnace wall temperature to reach the set temperature.Digital gas mass flow meter atmosphere automatic switching two way traffic, fast switching and stable time is short.Standard samples, convenient customer constant temperature correction coefficient.Software adaptive resolution of computer screens, each software automatically according to the computer screen size to adjust the curve display mode. Support for notebook, desktop; Support the Win2000, XP, VISTA, Windows 7 operating system, etcSupport user programming procedures, to achieve fully automated measuring step. Software provides dozens of commands, users can according to your own measurement steps, and combined the orders, and save. Complex operation is simplified into a key operation.Parameters:Temperature range: RT-500℃Temperature resolution:0.01℃Heating rate: 1~80℃/min  Cooling rate:1~30℃/min  DSC range: 0~±500mWDSC resolution: 0.02mWWorking power: AC 220V 50Hz 300W or otherGas pressure:0.2MPaGas flow accuracy: 0.2mL/minConfiguration list:A DSC machine300 Aluminium cruciblesA power cords and a USB cableA CD (contains software and operations video)Oxygen airway and nitrogen airway, each 5mA operation manual 

Classification


Get A Quote

Note: Please leave your contact information and our professionals will contact you as soon as possible!

Submit